Classifier Configuration - ZyXEL Communications XS1930-12HP User Manual

Hide thumbs Also See for XS1930-12HP:
Table of Contents

Advertisement

Click Advanced Application > Classifier in the navigation panel to display the configuration screen as
shown.
Figure 130 Advanced Application > Classifier
The following table describes the labels in this screen.
Table 81 Advanced Application > Classifier
LABEL
Index
Active
Weight
Name
Match Count
Rule
Clear

21.3 Classifier Configuration

Use the Classifier Configuration screen to define the classifiers. After you define the classifier, you can
specify actions (or policy) to act upon the traffic that matches the rules. To configure policy rules, refer
to
Chapter 22 on page
In the Classifier Status screen click Classifier Configuration to display the configuration screen as shown.
Chapter 21 Classifier
DESCRIPTION
This field displays the index number of the rule. Click an index number to edit the rule.
This field displays Yes when the rule is activated and No when it is deactivated.
This field displays the rule's weight. This is to indicate a rule's priority when the match order is set
to manual in the Classifier > Classifier Configuration > Classifier Global Setting screen.
The higher the number, the higher the rule's priority.
This field displays the descriptive name for this rule. This is for identification purpose only.
This field displays the number of times a rule is applied. It displays '-' if the rule does not have
count enabled.
This field displays a summary of the classifier rule's settings.
Select Classifier, enter a classifier rule name and then click Clear to erase the recorded
statistical information for that classifier, or select Any to clear statistics for all classifiers.
188.
XS1930 Series User's Guide
180

Advertisement

Table of Contents
loading

Table of Contents