Spi Trigger - Rigol 2000 Series User Manual

Digital oscilloscope
Hide thumbs Also See for 2000 Series:
Table of Contents

Advertisement

RIGOL

SPI Trigger

Trigger on the data pattern on the specified edge. When using SPI trigger, you need
to specify the SCL and SDA data sources. Below is the sequence chart of SPI bus data
transmission.
Processor 1[SPI Host]
Serial Data Line Buffer
(SPIxRXB)
Shift Register
Highest Bit
Serial Transmission Buffer
(SPIxTXB)
SPI Buffer
SPIxBUF
Trigger Type:
Press Type to open the trigger type list. Rotate
"SPI". At this point, the trigger setting information as shown in the figure below is
displayed at the upper right corner of the screen. For example,
The trigger type is SPI trigger; the trigger source is CH1; the trigger level is 0.00 V.
Source Selection:
Press SCL and SDA to specify the data sources of SCL and SDA respectively. They
can be set to CH1, CH2 or any channel of D0-D15. For the details, please refer to the
introduction in "Trigger Source". The current trigger source is displayed at the
upper right corner of the screen.
Note:
Select channel with signal input as trigger source to obtain stable trigger.
5-44
SDOx
SDIx
SPIxSR
Lowest Bit
SCKx
Figure 5-15 SPI Trigger
Chapter 5 To Trigger the Oscilloscope
SDIx
SDOx
Serial Clock
SCKx
and press down
Processor 2[SPI Slave]
Serial Data Line Buffer
(SPIxRXB)
Shift Register
SPIxSR
Highest Bit
Lowest Bit
Serial Transmission Buffer
(SPIxTXB)
SPI Buffer
SPIxBUF
to select
MSO2000A/DS2000A User Guide
.

Advertisement

Table of Contents
loading

Table of Contents