zCommand transmission method
Transmit using the following command formats.
Transmitted data
Hash value
("Connection method"
(
page 108))
32 bytes
Received data
'0'
0x30
1 byte
Error response
"ERR1"
Undefined control command
"ERR2"
Out of parameter range
"ERR3"
Busy state or no-acceptable period
"ERR4"
Timeout or no-acceptable period
"ERR5"
Wrong data length
"ERRA"
Password mismatch
Header
'0'
'0'
0x30
0x30
1 byte
1 byte
Header
'0'
0x30
1 byte
Error message
4 bytes
Technical information
Data section
Control command
(ASCII string)
Undefined length
Data section
Control command
(ASCII string)
Undefined length
Termination symbol
ENGLISH - 109
Termination
symbol
(CR)
0x0d
1 byte
Termination
symbol
(CR)
0x0d
1 byte
(CR)
0x0d
1 byte

Advertisement