Network And Remote Control Operation; Remote Control Interfaces And Protocols - R&S SGU100A Getting Started

Sgma upconverter
Table of Contents

Advertisement

®
R&S
SGU100A
2. Enter the first characters of the topic you are interested in. The entries starting
with these characters are displayed.
3. Press the [ENTER] key to display the help topic.
The corresponding help topic is displayed.
5.2

Network and Remote Control Operation

As an alternative to operating the R&S SGU interactively via the R&S SGMA-GUI,
one can also control the R&S SGU using programmed commands from a remote
PC.
The description in this section requires basic knowledge of the remote con-
trol operation. Definitions specified in the SCPI standard are not provided.
Nevertheless, you can find some basic information to the SCPI syntax,
command lists, and general programming recommendations in section
Remote Control Basics of the user manual. In addition, this chapter pro-
vides information on the status reporting system of the instrument.
5.2.1

Remote Control Interfaces and Protocols

The instrument supports several interfaces for remote control. The following table
gives an overview.
Table 5-1: Remote control interfaces and protocols
Interface Protocols
Local
HiSLIP High-Speed LAN Instrument Proto-
Area Net-
col (IVI-6.1)
work
VXI-11
(LAN)
socket communication (Raw Ethernet,
simple Telnet)
USB
USBTMC
Getting Started 1418.2070.02 ─ 08
Network and Remote Control Operation
Remarks
A LAN connector is located on the
rear panel of the instrument.
The interface is based on TCP/IP
and supports various protocols.
For details, see
"LAN
Interface",
A USB connector is located on the
rear panel of the instrument.
For details, see
"USB
Interface",
Instrument Control
Chapter 5.2.1.1,
on page 47
Chapter 5.2.1.2,
on page 51
46