Identcontrol compact with interface for profibus dp
Hide thumbs Also See for IC-KP2-1HB6-V15B:
Table of Contents

Advertisement

IC-KP2-1HB6-V15B
Commands
<T>
<TagType>
<WordAddr>
<WordNum>
<Year>
7.3.10
Fault/Status messages
Status
00h
FFh
Error messages which triggered the identification system
Status
01h
02h
03h
04h
05h
06h
07h
08h
09h
0Ah
0Bh
0Ch
0Dh
0Eh
0Fh
Error messages sent by the bus connection
Status
10h
20h
40h
76
: 1 bit, toggle bit
: 2 ASCII characters, for example: '02' for IPC02
: 2 bytes, word start address in the data carrier, range from 0000h to
FFFFh, depending on data carrier type.
: 4 bits, number of words to be read or written, range from 0h to Fh,
depending on data carrier type.
The following applies for IPC03: The word count 0h is used with the
word address 0000h to read the preset data range on the data carrier
("Default Read").
The following applies for IQC33: The word count parameter must be
even-numbered because of the block size of 8 bytes. The word
address then indicates the offset in 8-byte increments.
: 2 bytes ASCII, hexadecimal encoding, 00h ... 63h
Meaning
The command has been executed without error.
The command is processing.
Meaning
The battery of the read/write tag is weak.
Reserved
Reserved
Incorrect or incomplete command or parameter not in the valid range.
No data carrier in the detection range.
Hardware error, e.g. error during self-test or R/W head defect.
Internal device error.
Reserved
The parameterized tag type is not compatible with the connected reading head.
Several tags in the detection range (UHF).
Reserved
Reserved
Reserved
Internal buffer overflow.
Reserved
Meaning
Reserved
Reserved
Incorrect or incomplete command or parameter not in the valid range.
TCP/IP: The specified length of the message does not match the actual length.