Pepperl+Fuchs IC-KP2-1HB6-V15B Manual page 64

Identcontrol compact with interface for profibus dp
Hide thumbs Also See for IC-KP2-1HB6-V15B:
Table of Contents

Advertisement

IC-KP2-1HB6-V15B
Commands
Set tag ID code (TI)
Command:
Byte
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Response:
Byte
Byte 0
Byte 1
Byte 2
Byte 3
This command restricts the execution of all other read/write commands to the
read/write tag with the specified ID code. This also applies if another read/write
tag is located within the detection range. A targeted response is achieved from the
read/write tag as a result.
<ByteNum> = 0h: Do not make a selection. An ID code is not specified in the
telegram.
<ByteNum> = 8h (System IQ): Make a selection. An ID code must be specified in
the telegram.
<ByteNum> = 0h deletes this filter.
Note!
The TI command only adjusts a setting in the reading head. There is no HF
communication with the read/write tags.
64
Content
Command code (BCh)
ID length/Channel/Toggle bit
Data
Data
Data
Data
Content
Command code (BCh)
Reserved/Channel/Toggle bit
Status
Reply counter
Bit no.
7
6
5
4
3
1
0
1
1
1
<ByteNum>
<Channel>
<ID code>
<ID code>
<ID code>
<ID code>
Bit no.
7
6
5
4
3
1
0
1
1
1
<ByteNum>
<Channel>
<Status>
<ReplyCounter>
2
1
0
1
0
0
<T>
2
1
0
1
0
0
<T>