Pepperl+Fuchs IC-KP2-1HB6-V15B Manual page 61

Identcontrol compact with interface for profibus dp
Hide thumbs Also See for IC-KP2-1HB6-V15B:
Table of Contents

Advertisement

IC-KP2-1HB6-V15B
Commands
Single write fixcode (SX)
Command:
Byte
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
...
1)
Byte N
Table 7.7
Response:
Byte
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
The R/W head makes only one attempt to write a read only code.
IPC11:
IDC-...-1K:
Type IDC-...-1K tags can be programmed in such a way that they are compatible
with the type ICC-... read only carriers. This programming occupies the first 8
bytes in the tag. The read/write commands can be used to access the remaining
memory.
Content
Command code (1Fh)
FixLen/Ident channel/Toggle bit
FixType
FixType
Data 00h ... FFh
Data 00h ... FFh
Data 00h ... FFh
1) N = <FixLen> + 3
Content
Command code (1Fh)
FixLen/Ident channel/Toggle bit
Status
Reply counter
not used
not used
not used
not used
<FixLen>
= 5
<FixType>
= '02' ASCII (30h 32h), the read only code cannot be changed
'11' ASCII (31h 31h), the read only code can be overwritten
<FixLen>
= 7
The first 3 bytes are hexadecimal (0h ... Fh), the last 4 bytes
are decimal (0d ... 9d).
<FixType>
= '52' ASCII (35h 32h), the read only code can be overwritten
<Data>
= (Byte 1 to 3): 0x30 ... 0x39; 0x41...0x46
(Byte 4 to 7): 0x30...0x39
Bit no.
7
6
5
4
3
0
0
0
1
1
<FixLen>
<Channel>
<FixType> (high byte)
<FixType> (low byte)
<Data>
<Data>
<Data>
Bit no.
7
6
5
4
3
0
0
0
1
1
<FixLen>
<Channel>
<Status>
<ReplyCounter>
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2
1
0
1
1
1
<T>
2
1
0
1
1
1
<T>
-
-
-
-
-
-
-
-
-
-
-
-
61

Advertisement

Table of Contents
loading

Table of Contents