IC-KP2-1HB6-V15B
Commands
Write read only code IPC11 and IDC-..-1K
"Read-after-write" operating mode is not used.
Tags IPC11 can be programmed to behave like the IPC02 read only tag. To do
this, use the commands SX and EX. The code is read when tag type '02' or '11' is
set with the commands SF and EF.
Tags IDC-...- 1K can be programmed to behave like the ICC read only tag. This
programming occupies the first 8 bytes in the tag and occurs when the tag type
'50' is set with the commands SX or EX.
This code is read when tag type '52' is set with the commands SF or EF. If you use
the command SF or EF when tag type '50' is selected, the 4-byte read only code
of the tag is issued.
60