Pepperl+Fuchs IC-KP2-1HB6-V15B Manual page 57

Identcontrol compact with interface for profibus dp
Hide thumbs Also See for IC-KP2-1HB6-V15B:
Table of Contents

Advertisement

IC-KP2-1HB6-V15B
Commands
Single write configuration (SC)
Command:
Byte
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Response:
Byte
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
The R/W head makes exactly one attempt to write a word to the configuration
range ("Protection Word" or "Control Word") from the address <ConfAddr>.
The password mode must be active so that the R/W head can write to the
configuration range.
If the password mode is deactivated, every data word outside of the write-
protected range can be written to. If you would like to modify the write-protected
range, you must modify the "Protection Word" accordingly.
For example:
With the R/W head on channel 1, one data word (4 bytes) that does not contain
details of the address and data length should be transferred during each read
command (accessed with 00 byte and address 0000). Password mode must be
activated beforehand by transmitting the command Set password mode.
Content
Command code (12h)
Reserved/Ident channel/Toggle bit
Reserved
Address in the configuration range
Data 00h ... FFh
Data 00h ... FFh
Data 00h ... FFh
Data 00h ... FFh
Content
Command code (12h)
Reserved/Ident channel/Toggle bit
Status
Reply counter
not used
not used
not used
not used
Bit no.
7
6
5
4
3
0
0
0
1
0
-
-
-
-
<Channel>
-
-
-
-
-
<ConfAddr>
<Data byte 3>
<Data byte 2>
<Data byte 1>
<Data byte 0>
Bit no.
7
6
5
4
3
0
0
0
1
0
0
0
0
0
<Channel>
<Status>
<ReplyCounter>
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2
1
0
0
1
0
<T>
-
-
-
2
1
0
0
1
0
<T>
-
-
-
-
-
-
-
-
-
-
-
-
57