Powering Down

When the system is powered down, be sure the indicator lights on the CPU are
off and the fans have stopped before reapplying power.

6.2 Serial Control Device Startup

If you have not already done so, attach the serial control device to the enclosure
(see Chapter 4) and open your control program.
NetLinx

or Duet Compatible Devices

®
AMX AutoPatch distribution matrices can be controlled with any NetLinx
Duet compatible device. For control information, see the specific device's
product documentation.

APControl

If you are using APControl 3.0, install and open the program. Follow the
directions in the setup wizard. As part of the setup wizard, APControl will
discover the system's configuration information. From the Launchbar menu,
select Views / CrossBar and click on the crosspoints to execute switches.

APWeb

For startup information, see the APWeb Server Module documentation.

HyperTerminal

When power is applied to the enclosure(s), HyperTerminal displays a short
splash screen with basic information followed by "Ready" (see Figure 15). The
system is ready for a test switch (see page 7-2). If you need to see advanced
system information, enter ~scr! to view a long splash screen.
Short Splash Screen Example
AutoPatch EPICA signal router
Host software: v3.0.1
Hardware driver: v2.6.0 R
Built on Sep 14 2005 15:58:16
System PLD: A7
XNet address: 0x3774.(APSystem ID 0)
Ready
Figure 15: Example of Epica-256 splash screen information