Executing Switches
The following instructions provide command string formats for executing
switches by designating either an input or one or more outputs first.
To execute a switch, enter the Change command below. Replace the "#"s with
the level, input, and output number(s).
CL#I#O#T or CL#O#I#T
To cancel an incorrect or incomplete BCS command, enter "X".
Change Examples:
BCS Command
CL1I40O115T
CL1I6O12 47 95T
CL0O82I50T
CL2I6O81:85T
CL1 2I44O65 66T
CL0I237O4:7 9 13:16T
CL2I109X
BCS Command Table
The following table shows the BCS command characters (keys) that can be used
when executing switches. For a complete list of the BCS command characters,
see the BCS Command Table on page 1-5.
Key
Function
Change
C
L
Level
"
0
" - "
9
"
Number
I
Input
O
Output
" "
Space
:
Colon
T
Take
Exit
X
2-2
Action
Switches Input 40 to Output 115 on Level 1
Switches Input 6 to Outputs 12, 47, and 95 on Level 1
Switches Input 50 to Output 82 on Level 0
Switches Input 6 to Outputs 81, 82, 83, 84, 85, on Level 2
Switches Input 44 to Outputs 65 and 66 on Levels 1 and 2
Switches Input 237 to Outputs 4, 5, 6, 7, 9, 13, 14, 15, and 16
on Level 0
Cancels the incomplete command
Description
Initiates a Change (execute switch) command; this must precede
the level, input, and output specification
Indicates the number(s) following is the level
Identifies input, output, and level values; use multiple digits to
enter larger numbers
Indicates the number(s) following is an input (source)
Indicates the number(s) following is an output(s) (destination)
O
is the letter O, not the number zero (0)
Note:
Separates numbers in entries containing multiple numbers
Specifies a range of output numbers in entries containing multiple
numbers
Executes a command
Exits, or cancels, the command being entered