  • Page 1 AXC-EM Enhanced Master Card A x c e s s C e n t ra l C o n t r o l l e r s...
  • Page 2 RMA number. AMX Corporation is not liable for any damages caused by its products or for the failure of its products to perform. This includes any lost profits, lost savings, incidental damages, or consequential damages. AMX Corporation is not liable for any claim made by a third party or by an AMX Dealer for a third party.
  • Page 3: Table Of Contents

    Specifications ... 1 Setting the RS-232 Communications DIP Switch... 2 Installation ... 3 AXLink Wiring... 3 RS-232 Connector Wiring ... 3 Replacing the Battery ... 4 Upgrading the Memory Chips... 4 Programming... 5 AXC-EM Enhanced Master Card Table of Contents...
  • Page 4 Table of Contents AXC-EM Enhanced Master Card...
  • Page 5: Product Information

    Product Information The AXC-EM Enhanced Master Card (FIG. 1) controls system operation and executes Axcess programs. It coordinates the activities of up to 255 devices. These include the following: Control cards Bus controllers Various input devices, such as: AMX TiltScreens...
  • Page 6: Setting The Rs-232 Communications Dip Switch

    AXlink Status LED To ensure the integrity of your Axcess program, you can use two AXC-EMs, each loaded with the same program. Should the primary AXC-EM's control of AXlink be interrupted, the secondary AXC-EM will automatically take control. Setting the RS-232 Communications DIP Switch Use the 8-position DIP switch to set the communication parameters.
  • Page 7: Installation

    Connect the wiring from the CardFrame to the external AXlink devices, as shown in FIG. 2. FIG. 2 AXLink Wiring diagram RS-232 Connector Wiring The following table describes signal definitions for the 9-pin RS-232 communication port connector (P2) on the front of the AXC-EM. RS-232 Pinout Information Pin Signal Function...
  • Page 8: Replacing The Battery

    There are two lithium batteries on the AXC-EM. The batteries protect the memory on the AXC-EM. While the DC power is on, the batteries are not used. The battery life is five years. At the time of installation, record when you need to replace the batteries.
  • Page 9: Programming

    Use an AMX RS-232 cable (FG 10-726) to connect your PC to the AXC-EM to download the Axcess program. Do not use a null modem cable, as Pin 7 on the AXC-EM connector is reserved for the AMX Field Programming Unit (ALF).
  • Page 10 Product Information AXC-EM Enhanced Master Card...
  • Page 11 Product Information AXC-EM Enhanced Master Card...
  • Page 12 ATLANTA • BOSTON • CHICAGO • CLEVELAND • DALLAS • DENVER • INDIANAPOLIS • LOS ANGELES • MINNEAPOLIS • PHILADELPHIA • PHOENIX • PORTLAND • SPOKANE • TAMPA 3000 RESEARCH DRIVE, RICHARDSON, TX 75082 USA • 800.222.0193 • 469.624.8000 • 469-624-7153 fax • 800.932.6993 technical support • www.amx.com...