USERS (Continued)
User Enable/Disable (By User Number)
User Number must be between 2 and 5000.
NOTE: Will Enable/Disable Users even if the User is associated with an enabled Group. Use Function 3 to disable a specific User
Number and their associated User Code. If the disabled User Code is entered, the lock will flash 1 Green and 4 Red Flashes (with
1 long and 5 short beeps) indicating that the User Code exists in memory, but is disabled. Function 4 will "undo" Function 3.
3. Disable User
4. Enable User
5. User Enable with Timeout
(Enter Timeout, XXX Hours)
(This Function enabled through keypad only)
With Function 5, User Numbers must be between 2-5000, hours must be between 001-999.
Function 5 can temporarily override a disabled User (disabled using Function 3 above).
Since this is a temporary feature, Function 5 can only be enabled using the keypad.
Example: Brian, User Number 1157, rarely works at the office, but when he does, enable him for his 8 hour work day by
entering Program Mode and pressing: ; 5 ; 1157 ; 008 :.
NOTE: Up to 4 Timeout Functions may be pending at any one time. An error beep will sound when attempting to program more
than 4 Timeout Functions.
User Lockout Mode
Prevents all User Codes (Except User 1 Code) from operating the lock. Note: No other programming
functions or schedules (including a DL-Windows data transfer) will re-enable Users. Users must be re-
enabled with Function 7. Note: Does not change the User enable/disable status. Note: If the lock
is currently in Passage Mode (door "unlocked") and Function 6 is programmed, the lock will remain in
Passage Mode.
6. Enable Total User Lockout Mode
(This Function enabled through keypad only)
7. Disable Total User Lockout Mode
(This Function enabled through keypad only)
8. Exit Program Mode
Allows Program Mode exit for keypads without hold-down functionality, such as some Wiegand readers with integral keypads.
9. Enable User 300
Service Code is a One-Time-Only Code. Once it is used, it is disabled until enabled again.
NOTE: User Number 297 is used to reset Service Code Use. See "Terminology Used in
this Manual" on page 7 for more information and examples regarding special Users 297-300.
10. Erase All Users Except the Master Code
(This Function enabled through keypad only)
Erases all User Codes except the Master Code (User 1).
Function 10 can only be performed using the keypad.
11. Reserved
22
Programming Functions (cont'd)
(Service Code)
[ _ _ _ _ ]
; 3
;
(User Number)
[ _ _ _ _ ]
; 4
;
(User Number)
; 5
;
[ _ _ _ _ ]
(User Number)
; 6 :
; 7 :
; 8 :
; 9 :
; 1 0
(User 1)
:
:
;
[ _ _ _ _ ]
:
(XXX Hours)
M
2
; 0 0 0 :
M
2
2
3
Need help?
Do you have a question about the Wireless Networx PDLN4100 and is the answer not in the manual?