Omni Out Delay
The omni outs can be delayed individually by up to 300 milliseconds. This can be used
to compensate for delays in multi-speaker sound reinforcement systems.
1. Use the [ /DELAY] button to locate DELAY page 4, as shown below.
2. Use the cursor buttons to select the delay parameters and the [ENTER]
button, PARAMETER wheel, or [–1/DEC] and [+1/INC] buttons to set
them.
Parameter
Range
ON/OFF
ON/OFF
DELAY
0–300 ms
Description
These switches are used to turn on and off the delays.
Delay can be specified in milliseconds, meters, or samples
("Setting 01V Preferences" on page 203). The maximum
delay in samples is fixed at 13229. The maximum delay in
milliseconds and meters depends on the sampling rate. At
44.1 kHz, for example, it is 300 milliseconds and 102.2
meters, respectively.