Symptom
Added channels to a mute group
but group muting does not work.
Cannot store an EQ program.
Cannot recall EQ programs to input
channels 17 through 24.
Cannot locate the aux send
panpots.
The bus master level faders work in
unison.
No output from the OMNI OUTs.
Cannot send channel signals to the
effects processors.
The effects send meters indicate
that signals are being sent to the
effects, but the processed sounds
cannot be heard.
Cannot store effects programs.
Cannot recall effects programs 19
and 42 to Effect 1.
Cannot feed effects return 1 to
Effect 1, or effects return 2 to Effect
2.
Cannot store dynamics programs.
Cannot store to scene memory 00.
Cannot store mix scenes.
Cannot recall mix scenes.
Help! I recalled a mix scene by
mistake.
The scene memory number keeps
flashing.
Recalling a mix scene doesn't
update some channels.
The specified fade time has no
effect.
Make sure that the mute group is enabled. See "Grouping Mutes" on
page 56 for more information.
EQ settings cannot be stored to preset programs 1 through 40. Try
storing to user programs 41 through 80. See "Storing EQ Programs"
on page 68 for more information. EQ settings of channel 17 through
24 can not be stored.
EQ programs cannot be recalled to input channels 17 through 24.
Aux send panpots are only available when aux sends are paired. See
"Pairing Aux Sends" on page 101 for more information.
Probably because the bus outs are paired. See "Pairing Bus Outs" on
page 111 for more information.
Check the OMNI OUT source assignments. See "Assigning Omni
Outs" on page 116 for more information.
If the effects sends are configured post-fader, the regular channel
fader must be raised in addition to the aux send fader. See "Using the
Effects" on page 123 for more information.
Processed signals are returned via the effects returns. See "Returning
Processed Signals" on page 124 for more information.
Effects settings cannot be stored to preset programs 1 through 42. Try
storing to user programs 43 through 99. See "Storing Effects Pro-
grams" on page 133 for more information.
These effects programs use the HQ. PITCH and FREEZE type effects
and can only be recalled to Effect 2. See "Preset Effects Programs" on
page 121 for more information.
This is to prevent signal loops. See "Using the Effects" on page 123 for
more information.
Dynamics settings cannot be stored to preset programs 1 through 40.
Try storing to user programs 41 through 80. See "Storing Dynamics
Programs" on page 174 for more information.
Scene memory 00 is a read-only memory. See "Scene Memory 00" on
page 185 for more information.
Is the selected scene memory protected? See "Protecting Scene Mem-
ories" on page 189 for more information.
Only scene memories that contain data can be recalled.
Use the Undo function to return to the previous mix settings. See
"Undoing Mix Scene Recalls" on page 189 for more information.
This is because a scene memory other than the one last recalled has
been selected but not recalled. See "Scene Memory Display Area" on
page 185 for more information.
Perhaps these channels are safe channels? See "Recalling Scene Data
Safely" on page 192 for more information.
Fade Time settings must be stored in mix scenes before they take
effect. See "Setting a Fade Time" on page 191 for more information.
Troubleshooting
Advice
01V—Owner's Manual
255

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

O1v

Table of Contents