Codabar Set Length 2 - Datalogic QuickScan QD24 Series Product Reference Manual

General purpose handheld area imager bar code reader
Hide thumbs Also See for QuickScan QD24 Series:
Table of Contents

Advertisement

1D Symbologies

Codabar Set Length 2

This feature specifies one of the bar code lengths for
abar Length Control on page
on page 243
Mode, or the second fixed length if in
includes the bar code's start, stop, check and data characters. The length must include at least
one data character.
The length can be set from 3 to 50 characters. A setting of 0 specifies to ignore this length
(only one fixed length).
Table 14
provides examples for setting Length 2. See
ting this feature.
Table 14. Codabar Length 2 Setting Examples
STEP
ACTION
Desired Setting (and pad
1
with leading zeroes)
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODABAR LENGTH 2 SETTING
Scan Two Characters From
4
Appendix D, Keypad
5
Scan ENTER/EXIT PROGRAMMING MODE
$CCBL2
Select Codabar Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
Product Reference Guide
147. Length 2 is the maximum label length if in
EXAMPLES
00 Ignore This
Length
'0' and '0'
50 = Length 2 is 50 Characters
DEFAULT
Enter/Exit Programming Mode
Codabar Length Control on page 147Cod-
Fixed Length on page 243
page 243
for detailed instructions on set-
07 Characters
15 Characters
'0' and '7'
'1' and '5'
~
CANCEL
Variable Length
Mode. The length
50 Characters
'5' AND '0'
149

Hide quick links:

Advertisement

Table of Contents
loading