Keyboard Interface; Wedge Quiet Interval - Datalogic QuickScan QD24 Series Product Reference Manual

General purpose handheld area imager bar code reader
Hide thumbs Also See for QuickScan QD24 Series:
Table of Contents

Advertisement

References

Keyboard Interface

Wedge Quiet Interval

Specifies the amount of time the reader looks for keyboard activity before it breaks the key-
board connection in order to transmit data to host. The range is from 0 to 990ms in 10ms
increments.
This feature applies ONLY to the Keyboard Wedge interface.
NOTE
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with lead-
ing zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3. Go to
page 45
Mode.
4. Scan the bar code: SELECT WEDGE QUIET INTERVAL SETTING.
5. Scan the appropriate two digits from the keypad in
duration which was determined in the steps above. You will hear a two-beep indication
after the last character.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not
save the entry string. You can then start again at the beginning.
NOTE
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit.
This completes the procedure to set the Wedge Quiet Interval. See
of how to set this feature.
Table 32. Wedge Quiet Interval Setting Examples
STEP
ACTION
1
Desired Setting
Divide by 10 (and pad with
2
leading zeroes)
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT WEDGE QUIET INTERVAL SETTING
Scan Two Characters From
5
Appendix D, Keypad
6
Scan ENTER/EXIT PROGRAMMING MODE
240
and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Prog.
EXAMPLES
'0' and '1'
Appendix D,
10ms
150ms
01
15
'1' and '5'
QuickScan™ I QD24XX/QBT24XX/QM24XX
Keypad, that represent the
Table 32
for some examples
600ms
850ms
60
85
'6' and '0'
'8' and '5'

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents