Enter/Exit Programming Mode
GS1 DataBar™ Omnidirectional 2D Component
This feature enables/disables a requirement that a 2D label component be decoded when a
base label for this symbology is decoded.
DEFAULT
$C4B2D01(CR)
GS1 DataBar™ Omnidirectional 2D Component =
2D component must be decoded
The following options apply to the GS1 DataBar™ Expanded (formerly RSS Expanded) symbol-
ogy.
GS1 DataBar™ Expanded Enable/Disable
When disabled, the reader will not read GS1 DataBar™ Expanded bar codes.
DEFAULT
$CXBEN01(CR)
GS1 DataBar™ Expanded = Enable
158
GS1 DATABAR™ EXPANDED
$C4B2D00(CR)
GS1 DataBar™ Omnidirectional 2D Component =
Disable (2D component not required)
$CXBEN00(CR)
GS1 DataBar™ Expanded = Disable