Datalogic Quickscan I Quick Reference Manual

Datalogic Quickscan I Quick Reference Manual

General purpose corded handheld linear bar code reader

Advertisement

Quick Links

Quickscan™ I
QD2200
QUICK REFERENCE GUIDE
General Purpose Corded
Handheld Linear Bar Code Reader

Advertisement

Table of Contents
loading

Summary of Contents for Datalogic Quickscan I

  • Page 1 Quickscan™ I QD2200 QUICK REFERENCE GUIDE General Purpose Corded Handheld Linear Bar Code Reader...
  • Page 2 Disclaimer Datalogic has taken reasonable measures to provide information in this manual that is complete and accurate, however, Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for inci- dental or consequential damages resulting from the use of this material.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS END USER SOFTWARE LICENSE AGREEMENT....V Software Product Policy ............IX Description ..............1 The Most Prompt Response at the Pos Check-out ..... 1 Comfort and Reliability ............1 Hands Free Stand/holder............2 Setting Up the Reader ............ 3 Connecting to the Host Interface..........
  • Page 4: End User Software License Agreement

    Datalogic grants to End User, a personal, non-exclusive, non-transfer- able, non sub licensable, revocable, limited license to use the Soft- ware, solely on the Datalogic Product in which it is embedded or for which it is intended for use, in machine-readable form only, solely for End User's internal business purposes.
  • Page 5 End User to promptly pay all (additional) license fees due and any further damages, if any. 2. License Fee License fees shall be due by End User to Datalogic according to the terms provided for in the relevant contract for the purchase of the Datalogic Product.
  • Page 6 IF ANY, WHETHER BASED UPON CONTRACT, TORT (INCLUDING NEGLI- GENCE), PRODUCT LIABILITY, STRICT LIABILITY, WARRANTY, OR ANY OTHER BASIS, EXCEED THE PRICE OR FEE PAID BY END USER FOR THE DATALOGIC PRODUCT. UNDER NO CIRCUMSTANCES SHALL DATALOGIC OR ITS LICEN-...
  • Page 7 All notices required or authorized under this Agreement shall be given in writing, and shall be effective when received, with evidence of receipt. Notices to Datalogic shall be sent to the attention of Datalogic IP Tech S.r.l., Legal & IP Department, Via San Vitalino 13, 40012 Calderara di Reno (Bolo- gna), Italy, or such other address as may be specified by Datalogic in writ- ing.
  • Page 8: Software Product Policy

    - END - Software Product Policy Datalogic reserves the right to ship its products with the latest version of software/firmware available. This pro- vides our customers with the very latest in Datalogic soft- ware technology.
  • Page 9 EULA NOTES QUICK REFERENCE GUIDE...
  • Page 10 EULA QUICKSCAN™ I QD2200...
  • Page 11: Description

    The QuickScan™ QD2200 imager is the 1D entry-level corded imager from Datalogic with a superior scanning perfor- mance in its category. It reliably reads any type of 1D bar- code from up close to a distance with ease in capturing long bar codes.
  • Page 12: Hands Free Stand/Holder

    Description Hands Free Stand/holder An accessory is available which holds the reader at a con- venient angle, allowing hands free scanning of items. It can also be used as a holder. QUICKSCAN™ QD2200...
  • Page 13: Setting Up The Reader

    Setting Up the Reader SETTING UP THE READER Follow the steps below to connect and get your reader up and communicating with its host. 1. Connect the Cable to the reader and the Host as shown below. 2. Configure the Interface (see page 7). 3.
  • Page 14: Connecting And Disconnecting The Cable

    CONNECTING AND Disconnecting the Cable CONNECTING AND DISCONNECTING THE CABLE When inserting the cable, make sure the connector clip is on the same side as the reader release hole. Insert the cable, it should click when it is fully inserted. To remove the interface cable from the reader, first locate the hole on the front of the handle.
  • Page 15: Using The Quickscan™ I Qd2200

    Successful reading is signaled by an audible tone plus a good-read green spot LED indicator. Refer to the Quickscan I QD2200 Product Reference Guide (PRG) for more information about this feature and other programmable settings.
  • Page 16: Parts Of The Reader

    Parts of the Reader PARTS OF THE READER 1. LED 2. Scan Window 3. Trigger 4. Cable Release Hole QUICKSCAN™ QD2200...
  • Page 17: Selecting The Interface Type

    For interfaces other than those listed in this manual, see the Quickscan™ I QD2200 Product Reference Guide (PRG), available online at www.datalogic.com. Interface Selection The reader will support all the following host interfaces: USB HID POS •...
  • Page 18: Usb Interface

    Configuring the Interface USB Interface The reader attaches directly to a USB host, or a powered USB hub, and is powered by it. No additional power supply is required. When using a USB interface, the reader auto- detects the USB cable and defaults to the USB keyboard interface.
  • Page 19 Configuring the Interface All other interfaces support ONLY the following Country Modes: U.S., Belgium, Britain, France, Germany, Italy, Spain, Sweden. COUNTRY MODE ENTER/EXIT PROGRAMMING MODE Country Mode = U.S. Country Mode = Belgium Country Mode = United Kingdom Country Mode = Croatia* Country Mode = Czech Republic* QUICK REFERENCE GUIDE...
  • Page 20 Configuring the Interface COUNTRY MODE (CONTINUED) Country Mode = Denmark* Country Mode = France Country Mode = French Canadian Country Mode = Germany Country Mode = Hungary* Country Mode = Italy Country Mode = Japanese 106-key* QUICKSCAN™ QD2200...
  • Page 21 Configuring the Interface COUNTRY MODE (CONTINUED) Country Mode = Lithuanian Country Mode = Norway* Country Mode = Poland* Country Mode = Portugal* Country Mode = Romania* Country Mode = Slovakia Country Mode = Spain QUICK REFERENCE GUIDE...
  • Page 22 Configuring the Interface COUNTRY MODE (CONTINUED) Country Mode = Sweden Country Mode = Switzerland* Supports only the interfaces listed in the Country Mode feature description. QUICKSCAN™ QD2200...
  • Page 23: Programming

    Programming PROGRAMMING The reader is factory-configured with a set of standard default features. After scanning the interface bar code from the Interfaces section, select other options and cus- tomize your reader through use of the programming bar codes available in the Quickscan™ I QD2200 PRG. Check the corresponding features section for your interface, and also the Data Editing and Symbologies chapters of the PRG.
  • Page 24: Reading Parameters

    Reading Parameters READING PARAMETERS Move the reader toward the target and center the illumi- nation system to capture and decode the image. See "Using the Quickscan™ I QD2200" on page 5 for more information. The illuminator will remain on until the symbol is decoded.
  • Page 25: Operating Modes

    Operating Modes GREEN SPOT DURATION (CONTINUED) Long (800 ms) ★ = default value OPERATING MODES Scan Mode The reader can be set to operate in one of several scan- ning modes. See the PRG for more information and set- tings for any of the following options: This mode is associated with the Trigger Single (Default) typical handheld reader operation.
  • Page 26 Operating Modes The reader illuminator flashes on and off Flashing - regardless of the trigger status. Code reading takes place only during the Flash On Time . Double Read Timeout prevents undesired multiple reads. No trigger pull is required to read a bar Stand Mode - code.
  • Page 27 Operating Modes Always ON Stand Mode Trigger Object Sense ★ = default value QUICK REFERENCE GUIDE...
  • Page 28: Technical Specifications

    120000 lux Cable Length Refer to www.datalogic.com OPTICAL CHARACTERISTICS Tilt Tolerance ± 45° Pitch Tolerance ± 65° Skew Tolerance ± 65° Field of View HORIZONTAL 56° +/- 2° (Datalogic Test minimum 15% Chart) a. Based on ISO 15423 specifications. QUICKSCAN™ QD2200...
  • Page 29 Code 128; Code 128 ISBT; Interleaved 2 of 5; Standard 2 of 5; Interleaved 2 of 5 CIP (HR); Industrial 2 of 5; Discrete 2 of 5; Datalogic 2 of 5 (China Post Code/Chinese 2 of 5); IATA 2of5 Air cargo code; Code 11; Codabar; Codabar (NW7); ABC Codabar;...
  • Page 30: Led And Beeper Indications

    LED and Beeper Indications LED AND BEEPER INDICATIONS The reader’s beeper sounds and its illumination flashes or changes color to indicate various functions or errors on the reader. A “Green Spot” also lights to indicate a good read. The tables below list these indications. Refer to the PRG for a more detailed list.
  • Page 31: Troubleshooting

    Troubleshooting TROUBLESHOOTING PROBLEM POSSIBLE SOLUTION POSSIBLE CAUSE Check system power. No power to the Ensure power supply imager. Nothing happens is connected. when the scan button Interface or Ensure all cable is pulled. power cables are connections are loose. secure. Ensure reader is Reader not programmed to read...
  • Page 32: Warranty

    Datalogic, unless otherwise agreed in an applicable writing by Datalogic. Datalogic will not be liable under the warranty if the Product has been exposed or subjected to any: (1) maintenance, repair, installation, han- dling, packaging, transportation, storage, operation or use that is improper or otherwise not in compliance with Datalogic’s instruction;...
  • Page 33: Ergonomic Recommendations

    Hover over the Support & Service menu for access to Ser- vices and Technical Support. Reseller Technical Support An excellent source for technical assistance and informa- tion is an authorized Datalogic reseller. A reseller is acquainted with specific types of businesses, application QUICK REFERENCE GUIDE...
  • Page 34: Cleaning Procedure

    CAUTION: DO NOT use abrasive pads or cleaning agents. Common Cleaning Solutions The cleaners and disinfectants listed below are recom- mended for use on Datalogic’s Quickscan 2200 Enclosures: CLEANERS DISINFECTANT Formula 409® Glass and Clorox® Bleach (diluited 10:1)
  • Page 35: Cleaning Enclosure And Window Surfaces

    Cleaning Procedure Cleaning enclosure and window surfaces 1. Moisten a soft cloth with a recommended cleaning solution. Be sure to apply the solution to your cloth first. Wring excessive liquid from the cloth. 2. Use the cloth to wipe down the surface of the unit. Use cotton swabs, lightly moistened, to reach in cor- ners and crevices.
  • Page 36 Cleaning Procedure QUICKSCAN™ QD2200...
  • Page 37 ©2023 Datalogic S.p.A. and /or its affiliates. • All rights reserved • Without limiting the rights under copyright, no part of this documentation may be reproduced, stored in or introduced into a retrieval system, or transmitted in any form or by any means, or for any purpose, without the express written permission of Datalogic S.p.A.

This manual is also suitable for:

Qd2200