Pulse Output Destination Device And Rotation Direction Output Indicator Lamp - Mitsubishi Electric Melsec-F FX3GC Series User Manual

Hide thumbs Also See for Melsec-F FX3GC Series:
Table of Contents

Advertisement

FX
/FX
/FX
/FX
/FX
3S
3G
3GC
3U
3UC
Built-in Positioning Functions
13.1.6

Pulse Output Destination Device and Rotation Direction Output Indicator Lamp

1. If transistor outputs from the main unit are used for positioning
Signal
"Pulse output
destination
device" (pulse
train) signal
"Rotation
direction output"
(direction) signal
*1.
The output LED is kept ON in the FX
PLC User's Manual - Positioning Control Edition
LED status during
execution of
positioning
instruction
Turned on and off at
The pulse outputting operation is controlled by the positioning instruction.
*1
high speed
The PLC may exhibit the following status:
1) The operation of the positioning instruction is completed.
2) The positioning instruction turns ON, but an operation error is detected.
OFF
The instruction, therefore, is not being executed. To check the error,
refer to the following section:
ON
Operation is being performed in the forward rotation direction.
The PLC may exhibit the following status:
1) The positioning instruction turns ON, and operation is being performed
in the reverse rotation direction.
OFF
2) The positioning instruction turns ON, but an operation error is detected.
The instruction, therefore, is not being executed. To check the error,
refer to the following section:
3U
Description
Refer to Subsection 13.2.1 "Error code check method".
Refer to Subsection 13.2.1 "Error Code Check Method".
PLC.
13 Troubleshooting
13.1 LED Indicator Lamp Check
B - 181
A
B
Apx.