Mitsubishi Electric Melsec-F FX3GC Series User Manual page 82

Hide thumbs Also See for Melsec-F FX3GC Series:
Table of Contents

Advertisement

FX
/FX
/FX
/FX
/FX
3S
3G
3GC
3U
3UC
Built-in Positioning Functions
2. Source internal output circuit
FX
- MT/DSS
3UC
Main unit
*1.
To ground the unit, refer to the servo amplifier (drive unit) manual. If the grounding method is not
specified, carry out class-D grounding.
*2.
For MELSERVO Series amplifiers, use a sink output type FX
B - 38
PLC User's Manual - Positioning Control Edition
Y0
Y4
+V0
5 to 24V DC
Pulse train signal
Direction signal
Grounding
3UC
2 Specifications
2.5 Output Specifications
*2
Servo amplifier
(Drive unit)
*1
Series main unit .