Mitsubishi Electric Melsec-F FX3GC Series User Manual page 184

Hide thumbs Also See for Melsec-F FX3GC Series:
Table of Contents

Advertisement

FX
/FX
/FX
/FX
/FX
3S
3G
3GC
3U
3UC
Built-in Positioning Functions
6) Interrupt input signal logical NOT
Turn the "Interrupt signal logic reverse" relay ON or OFF (see the following table) to specify the logic of
the interrupt input signal. However, if the user interrupt input command is set for the pulse output
destination device, the interrupt input signal logical NOT function cannot be used.
Pulse output
destination device
D
1
D
1
D
1
D
1
*1.
Y003 is available only when two high-speed output special adapters are connected to the FX
1. Interruption positioning operation
The interruption positioning operation is described below assuming that Y000 is specified as the pulse output
destination device by
For this reason, if Y001, Y002, or Y003 is specified, it is necessary to change the output number of each
related flag.
Speed
Instruction execution
Interrupt input (X000)
"Instruction
execution complete" flag
M8029
1) Execute the Interrupt Positioning (DVIT) instruction.
2) Transfer operation will be performed in the direction specified by the sign attached to the number of
output pulses (specified by
).
S
2
3) If interrupt input X000 is turned on, pulses will be output until the number of output pulses reaches the
number specified by
4) The "instruction execution complete" flag (M8029) will turn on, and the interruption positioning operation
will be completed.
B - 140
PLC User's Manual - Positioning Control Edition
"Interrupt signal logic
reverse" relay
M8347
= Y000
M8357
= Y001
M8367
= Y002
*1
M8377
= Y003
.
D
1
 For details on related flags, refer to Section 4.1 to Section 4.4, or Section 9.2.
Acceleration
time
(D8348)
Bias speed
(D8342)
) at the speed specified by the output pulse frequency (specified by
S
1
, and then the operation will stop.
S
1
 For details on "Instruction execution complete" flag, refer to Subsection 4.7.4.
9 One-speed Interrupt constant quantity feed - DVIT Instruction
OFF: Positive logic (Turning the input ON will turn on
the interrupt input signal.)
ON:
Negative logic (Turning the input OFF will turn
on the interrupt input signal.)
Deceleration
Maximum speed
(D8344,D8343)
Output pulse
S
frequency
2
Number of output
pulses S
9.3 Function and Operation
Description
PLC.
3U
time
(D8349)
1
Time
ON