Mitsubishi Electric Melsec-F FX3GC Series User Manual page 217

Hide thumbs Also See for Melsec-F FX3GC Series:
Table of Contents

Advertisement

FX
/FX
/FX
/FX
/FX
3S
3G
3GC
3U
3UC
Built-in Positioning Functions
3
Click on the «Positioning» tab, and then set Y000 (pulse output destination)
as follows.
Before clicking on the "Positioning" tab, click on the «Memory Capacity» tab, and then enter a check in the
"Positioning Instruction Settings" check box. After entering a check, positioning data can be set.
*1.
Only available for FX
4
Click on the "Individual setting" button. The "Positioning Instruction
Settings" screen will appear. In this screen, click on the «Y0» tab to display
the positioning table for Y000 (pulse output destination). Set the data in the
positioning table as follows:
PLC User's Manual - Positioning Control Edition
and FX
PLCs.
3U
3UC
12.4 Positioning Using Batch Setting Method
Setting item
Bias Speed [Hz]
Max. Speed [Hz]
Creep Speed [Hz]
Zero Return Speed [Hz]
Acceleration Time [ms]
Deceleration Time [ms]
Interrupt Input for DVIT Instruction
Setting item
Rotation Direction Signal
Head Address
Positioning Instruction
No. 1
Pulse (Pls)
Frequency (Hz)
Positioning Instruction
No. 2
Pulse (Pls)
Frequency (Hz)
Positioning Instruction
No. 3
Pulse (Pls)
Frequency (Hz)
Positioning Instruction
No. 4
Pulse (Pls)
Frequency (Hz)
12 Examples of Programs
Setting value
500
100,000
1000
50,000
100
100
*1
X000
Setting value
Y004
R0
DDRVI
(drive to increment)
999,999
30,000
DDRVI
(drive to increment)
-999,999
30,000
DDRVA
(drive to absolute)
500,000
100,000
DDRVA
(drive to absolute)
100
100,000
B - 173
A
B
Apx.