FX
/FX
/FX
/FX
/FX
3S
3G
3GC
3U
3UC
Built-in Positioning Functions
2.5.4
FX
Series main unit (Transistor Output)
3U
This section describes the transistor output specifications of the FX
simultaneous turning-on rate is restricted for the output extension units and the main unit. For details on the
restriction, refer to the following manual.
For MELSERVO Series amplifiers, use a sink input/sink output type PLC.
Item
External voltage
Maximum load
Open-circuit leakage current
ON voltage
Response time
Circuit insulation
Indication of output motion
Pulse output terminals Y000, Y001, and Y002 are high-speed response output terminals.
To use the positioning instruction, adjust the load current of the NPN open collector to 10 to 100 mA (5 to 24 V DC).
Item
Operation voltage range
Operation current range
Output frequency
PLC User's Manual - Positioning Control Edition
All outputs
Resistance load All outputs
Inductive load
All outputs
All outputs
All outputs
Y000 to Y002
OFFON
Y003 or more
Y000 to Y002
ONOFF
Y003 or more
All outputs
All outputs
Description
5 to 24 V DC
10 to 100 mA
100 kHz or less
Series main unit. Please note that the
3U
Refer to the FX
Transistor output specifications
5 to 30 V DC
The total load current of resistance loads per common termi-
nal should be the following value or less.
- 1 point output common:0.5 A
- 4 points output common:0.8 A
- 8 points output common:1.6 A
The total of inductive load per common terminal should be the
following value or less.
- 1 point output common:12 W/24 V DC
- 4 points output common:19.2 W/24 V DC
- 8 points output common:38.4 W/24 V DC
0.1 mA or less at 30 V DC
1.5 V or less
5 s or less at 10 mA or more (5 to 24 V DC)
0.2 ms or less at 200 mA (at 24 V DC)
5 s or less at 10 mA or more (5 to 24 V DC)
0.2 ms or less at 200 mA (at 24 V DC)
Photocoupler insulation
LED is lit when the photocoupler is driven.
2 Specifications
2.5 Output Specifications
Hardware Edition.
3U
Apx.
B - 35
A
B