M215 Microinverter // DATA
®
INPUT DATA (DC)
Commonly used module pairings
Maximum input DC voltage
Peak power tracking voltage
Operating range
Min/Max start voltage
Max DC short circuit current
OUTPUT DATA (AC)
Peak output power
Rated (continuous) output power
Nominal output current
Nominal voltage/range
Nominal frequency/range
Extended frequency range
2
Power factor
Maximum units per 20 A branch circuit
Maximum output fault current
EFFICIENCY
CEC weighted efficiency, 240 VAC
CEC weighted efficiency, 208 VAC
Peak inverter efficiency
Static MPPT efficiency (weighted, reference EN50530)
Night time power consumption
MECHANICAL DATA
Ambient temperature range
Dimensions (WxHxD)
Weight
Cooling
Enclosure environmental rating
Connector type
FEATURES
Compatibility
Communication
Integrated ground
Monitoring
Compliance
1. Suggestion only. Inverter self-limits DC inputs. Visit https://enphase.com/en-us/support/module-compatibility to determine module size compatibility.
2. Frequency ranges can be extended beyond nominal if required by the utility
To learn more about Enphase Microinverter technology, visit
© 2017 Enphase Energy. All rights reserved. All trademarks or brands in this document are registered by their respective owner.
2017-01-25
M215-60-2LL-S22-IG, M215-60-2LL-S25-IG
190 - 270+ W
1
48 V
27 V - 39 V
16 V - 48 V
22 V / 48 V
15 A
@208 VAC
225 W
215 W
1.03 A (A rms at nominal duration)
208 V / 183-229 V
60.0 / 57-61 Hz
57-62.5 Hz
>0.95
25 (three phase)
850 mA rms for 6 cycles
96.5%
96.5%
96.5%
99.4 %
65 mW max
-40ºC to +65ºC
171 mm x 173 mm x 30 mm (without mounting bracket)
1.6 kg (3.4 lbs)
Natural convection - No fans
Outdoor - NEMA 6
M215-60-2LL-S22-IG: MC4
M215-60-2LL-S25-IG: Amphenol H4
Compatible with 60-cell PV modules.
Power line
The DC circuit meets the requirements for ungrounded PV arrays in
NEC 690.35. Equipment ground is provided in the Engage Cable. No additional GEC or
ground is required. Ground fault protection (GFP) is integrated into the microinverter.
Enlighten Manager and MyEnlighten monitoring options
UL1741/IEEE1547, FCC Part 15 Class B, CAN/CSA-C22.2 NO. 0-M91, 0.4-04, and 107.1-01
This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014
and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,
for AC and DC conductors, when installed according manufacturer's instructions.
@240 VAC
225 W
215 W
0.9 A (A rms at nominal duration)
240 V / 211-264 V
60.0 / 57-61 Hz
57-62.5 Hz
>0.95
17 (single phase)
850 mA rms for 6 cycles