Parts And Tools Required - enphase IQ8MC Installation And Operation Manual

Ac module
Table of Contents

Advertisement

Parts and tools required

In addition to the microinverters, PV modules, and racking, you will need the following:
Enphase equipment
IQ Gateway: Required to monitor production. For installation information, refer to the
IQ Gateway Installation and Operation
Enphase Installer App: Download the Enphase Installer App, open it, and
log in to your Enphase Account. Use it later to scan the microinverter serial
numbers and connect to the IQ Gateway to track system installation
progress. To download, go to
right.
IQ Relay: Single-phase (Q-RELAY-1P-INT) or three-phase (Q-RELAY-3P-INT).
NOTE: The three-phase IQ Relay also provides phase coupling to allow microinverters on all
phases to communicate with the IQ Gateway. Use a Legrand phase coupler (LPC-01) for the
three-phase system for phase coupling if an IQ Relay is not installed in a three-phase system.
Tie wraps or IQ Cable Clip (ET-CLIP-100): Works with both single-phase and three-phase IQ Cable.
IQ Sealing Caps (Q-SEAL-10): For any unused connectors on the IQ Cable.
IQ Terminator (Q-TERM-R-10 for single-phase or Q-TERM-3P-10 for three-phase): Enphase
recommends one terminator for each AC cable segment end; typically, two are needed per branch
circuit.
IQ Disconnect Tool (Q-DISC-10).
IQ Field Wireable Connectors (male and female single-phase: Q-CONN-R-10M and Q-CONN-R-
10F; male and female three-phase: Q-CONN-3P-10M and Q-CONN-3P-10F).
IQ Cable:
Cable model
Single-phase
Q-25-10-240
Q-25-17-240
Q-25-20-200
Three-phase
Q-25-10-3P-200
Q-25-17-3P-160
Q-25-20-3P-160
IQ Raw Cable (Q-25-RAW-300 for single-phase, Q-25-RAW-3P-300 for three-phase): Length 300
m. Raw cable with no connectors.
Other items
• AC junction box
• Screwdrivers
• Wire cutters, clamp meter
• Torque wrench, sockets, and wrenches for mounting hardware
13
IQ8MC, IQ8AC, and IQ8HC Installation and Operation Manual
Manual.
https:/ /enphase.com/en-au/installers/apps
Connector spacing
PV module orientation
1.3 m
2.0 m
Landscape (60-cell)
2.3 m
Landscape (72-cell)
1.3 m
2.0 m
Landscape (60-cell)
2.3 m
Landscape (72-cell)
© 2023 Enphase Energy Inc. All rights reserved.
or scan the QR code at
Connector count
Portrait
Portrait
Android
iOS
per box
240
240
200
200
160
160
November 2023