GENERAL INFORMATION

Parts Identification

Listed below is a description of the system power source parts. Use Figures 1 & 2 as a guide.
1. CH 1 POWER RECEPTACLE - Provides power, tip ground, sensing circuitry and finger switch connection
from MBT system to handpiece connected to Channel 1 (CH 1).
2. CH 2 POWER RECEPTACLE - Provides power, tip ground, sensing circuitry and finger switch connection
from MBT system to handpiece connected to Channel 2 (CH 2).
3. CH 3 POWER RECEPTACLE - Provides power, tip ground, sensing circuitry and finger switch connection
from MBT system to handpiece connected to Channel 3 (CH 3).
4. POWER SWITCH - Turns system ON ("1") and OFF ("0"); controls input power to the system.
5. AUTO SNAP-VAC PORT - Quick connect fitting provides quick-rise vacuum for Sodr-X-Tractor,
ThermoPik and Dual ThermoPik handpieces. Vacuum is present when handpiece finger switch or optional
foot pedal is actuated. Vacuum ceases 1.2 seconds after switch (or foot pedal) released.
6. CONTROLLABLE PRESSURE PORT - Quick connect fitting with adjustable valve which provides
variable air flow for Mini ThermoJet handpiece (in Hot Jet Mode) and Sodr-X-Tractor handpiece. Air
pressure is present when handpiece finger switch or optional foot pedal is actuated. Air pressure ceases
1.2 seconds after switch (or foot pedal) is released.
7. DIGITAL READOUT - Provides a three digit display of the Current Channel (channel with illuminated LED;
CH 1, CH 2 or CH 3 ) temperature information. This includes: Operating Tip Temperature in Temperature
Display Mode (normal operation), Tip Offset Constant in Tip Offset Mode, Set Tip Temperature in Tip Set
Mode and other information in Calibration (CAL) Mode.
8. °F /°C KEY - Selects °F or °C display of Set and Operating Tip Temperatures and Tip Offset Constants.
9. °F LED - Illuminates when Set\ Operating Tip Temperatures and Tip Offset Constants are displayed in °F.
10. °C LED - Illuminates when Set\ Operating Tip Temperatures and Tip Offset Constants are displayed in °C.
11. CH 1 LED - Illuminates when Channel 1 (CH 1) is the "Current Channel" i.e., the channel (with connected
handpiece\tip) whose temperature information is displayed on the digital readout.
12. CH 2 LED - Illuminates when Channel 2 (CH 2) is the "Current Channel" i.e., the channel (with connected
handpiece\tip) whose temperature information is displayed on the digital readout.
13. CH 3 LED - Illuminates when Channel 3 (CH 3) is the "Current Channel" i.e., the channel (with connected
handpiece\tip) whose temperature information is displayed on the digital readout.
14. CH SELECT KEY - Selects the Current Channel (among "Active Channels" i.e., those with a connected
handpiece).
15. TIP SET KEY - Allows the operator to adjust the Set Tip Temperature for the handpiece\tip combination
connected to the Current Channel. Places the system in the Tip Set Mode.