PANEL CONTROLS (CONT'D)
11. Press the °F/°C Key several times to observe the alternating illumination of the °F & °C LEDs. Each
subsequent pressing of the key will turn one LED on and the other off. Also notice as the Digital
Readout changes to display the Operating Tip Temperature in °F when the °F LED is illuminated and in
°C when the °C LED is illuminated.
12. Press the TIP SET Key once to enter the Tip Temperature Set Mode. Immediately press & hold the
Scroll Down Key. Observe as the displayed Set Tip Temperature decreases first in 1° and then in 10°
increments (°C or °F). Release the key when the Digital Readout displays 288°C (550°F). Immediately
press the TIP SET Key once again (or wait 6 seconds) and observe the Operating Tip Temperature
decrease to 288°C (550°F).
13. Press the TIP SET Key once again and use the Scroll Up and Scroll Down Keys to enter your desired
SET Tip Temperature. Immediately press the TIP SET Key to exit the Tip Temperature Mode. This
enters the new Set Tip Temperature for the Current Channel (which you've already keyed in) into
system memory.
14. Press the TIP OFFSET Key. The TIP OFFSET LED will illuminate and the Digital Readout will display
the Tip Temperature Offset value for the Current Channel. As received from the factory, the Digital
Readout will display "3" FOR °C ("6" FOR °F). If the TIP OFFSET Key is immediately pressed again, or
if no other operation occurs within 5 seconds, the LED will turn off and the Digital Readout will revert to
the Temperature Display Mode (normal operation).