CHANNEL LED OPERATION
4. The Channel LED (CH 1, CH 2 or CH 3) of the first Active Channel encountered by the system (channel
with connected handpiece) will be illuminated. This is the Current Channel. If no channels are active,
"E-1" will be displayed on the Digital Readout and the CH 1 LED will be illuminated.
5. Disconnect the handpiece from the Power Receptacle associated with the Current Channel (e.g., If CH 1
LED is illuminated, disconnect the handpiece connected to CH 1). The unit will now select the next
Active Channel encountered as the Current Channel and illuminate the corresponding LED.
If no other Power Receptacles have handpieces attached, the CH 1 LED will be
illuminated and "E-1" will be displayed on the Digital Readout.
6. Reconnect the handpiece removed in step 5.
DIGITAL READOUT OPERATION
7. The Digital Readout provides a 3 digit display of the
Current Channel (CH 1, CH 2 or CH 3) temperature
information. The Digital Readout will show the Set
Tip Temperature in the Tip Temperature Set Mode, Tip
Temperature Offset values in Tip Temperature Offset
Mode and the True Operating Tip Temperature in the
Temperature Display Mode (normal operation).
28
NOTE
Figure 15. Digital Readout "888"