UT-4500 Series C- and Ku-Band Up Converters
Front Panel Operation
Finally, set the asynchronous character format. Use the keys to select the
parameter, and then use the keys to select the format. The available
choices (i.e., number of data bits; odd, even, or no parity; number of stop bits) are
8-N-1, 7-E-2, or 7-O-2. Press ENTER.
6.2.3.2.3 (REMOTE:) ETHERNET
The UT-4500 Series C- and Ku-Band Up Converters, as initially released,
do not feature a rear panel 'Ethernet' port. Only current production
units offer Ethernet Interface operation. See Chapter 4. FRONT AND
REAR PANEL CONNECTORS for more information.
On the top line, use the keys to select ADDRESS, GATEWAY, or SNMP. The
bottom line displays the read-only unit MAC address. Press ENTER.
6.2.3.2.3.1 (REMOTE:) ETHERNETADDRESS
Edit the Management IP Address and Range for the rear panel 'Ethernet'
100BaseTX port. Use the keys to select a digit, and then use the keys
to change that digit. Press ENTER.
6.2.3.2.3.2 (REMOTE:) ETHERNETGATEWAY
Edit the IP Gateway Address for the rear panel 'Ethernet' 100BaseTX port. Use
the keys to select a digit, and then use the keys to change that digit.
Press ENTER.
ADDRESS GATEWAY SNMP
MAC = 00-06-B0-00-00-0F
IP Address/Range:
192.168.001.002/24
Ethernet IP Gateway:
192.168.001.002
6–11
MN/UT4500.IOM
Revision 3