Error Processing; General Errors; Configuration Errors; Mode Errors - Comtech EF Data UT-4500 Series Installation And Operation Manual

C- and ku-band up converters
Hide thumbs Also See for UT-4500 Series:
Table of Contents

Advertisement

UT-4500 Series C- and Ku-Band Up Converters
Serial Interface Operation

8.8 Error Processing

8.8.1.1

General Errors

Any command or query may generate the following Error Responses instead of a
confirmation:
>DEV?COM CU CMD UNRECOGNIZED{cr}{lf}]
>DEV?COM IP INVALID PARAM{cr}{lf}]
>DEV?COM PE PARITY ERROR{cr}{lf}]
8.8.1.2

Configuration Errors

A Configuration command may generate the following Error Response:
>DEV?COM LO DEVICE IN LOCAL MODE{cr}{lf}]
8.8.1.3

Mode Errors

A Mode selection may generate the following Error Responses:
>DEV?COM AE ONLY VALID WHEN BACKUP{cr}{lf}]
>DEV?COM OE OFFLINE NOT AVAILABLE{cr}{lf}]
>DEV?COM CN COMMAND NOT AVAILABLE{cr}{lf}]
8.8.1.4

Time-Outs

The station M&C computer should attempt to execute any instruction at least
three times. The system assumes a time-out if there is no response within 500
milliseconds.
8–33
MN/UT4500.IOM
Revision 3

Advertisement