UT-4500 Series C- and Ku-Band Up Converters
Specifications
2.2.7
IF Input
2.2.7.1
Noise Figure
13 dB Maximum @ 0 dB Attenuation
2.2.7.2
Level
-35 dBm Typical
2.2.7.3
Range
Contact Comtech EF Data Product Support for your specific requirements.
• STANDARD:
• OPTIONAL:
2.2.7.4
Impedance
50Ω or 75Ω
2.2.7.5
Return Loss
23 dB minimum with I/O Module or Switch Module
2.2.8
RF Output
2.2.8.1
Output Level
• C-Band:+17 dBm @ 1 dB Compression
• Ku-Band: +10 dBm @ 1 dB Compression
2.2.8.2
Intermodulation
• C-Band: -50 dBc @ 0 dBm Output SCL
• Ku-Band: -38 dBc @ 0 dBm Output SCL
52 to 88 MHz or 104 to 176 MHz
50 to 90 MHz or 100 to 180 MHz
2–8