UT-4500 Series C- and Ku-Band Up Converters
Front Panel Operation
6.2.3.2 (CONFIG:) REMOTE (Remote Control) Submenu
Use the keys to select Local, SERIAL, or ETHERNET. Press ENTER.
6.2.3.2.1 (REMOTE:) Local
1) When you select Local mode, remote monitoring is possible, but
remote control is disabled.
2) A number of operations are possible in Local mode only. If you are
in Serial or Ethernet mode during such tasks, the unit alerts you to
this remote state:
Remote Mode: press ENTER
Press ENTER to switch to Local Mode to continue with your task, or
press CLEAR to exit the task and remain in the active mode.
6.2.3.2.2 (REMOTE:) SERIAL
On the top line, use the keys to set the mode to RS-232 or RS-485. Press
ENTER. On the bottom line, set the Serial address (Addr). Use the keys to
select a digit, and then use the keys to change that digit. The valid range of
addresses is from 001 (default) to 255.
Next, set the Baud rate. Use the keys to select a parameter, and then use
the keys to select your desired baud rate. Available choices are 1200, 2400,
4800, 9600 (default), 19K2, and 38K4.
Remote Control: Local
SERIAL
ETHERNET
for local mode, or CLEAR
Serial Mode = RS-232
Addr=001 Baud=9600 8-N-1
6–10
MN/UT4500.IOM
Revision 3