UT-4500 Series C- and Ku-Band Up Converters
Serial Interface Operation
4) If the converter is the primary converter, gg=P1 or P2 (single or
dual polarity system).
8.7.5.8

PACRMS (Packed Maintenance Status)

Description
Maintenance Status:
Confirmation:
8.7.5.9

PACRAS (Packed Alarm Status)

Description
Alarm Status:
Confirmation:
Details
<DEV/PACRMS_{cr}
>DEV/PACRMS_aabbccddeeeffgghhii{cr}{lf}] where:
aa
= V15 scaled 123mV per count (0x00 - 0xFF)
bb
= V14 scaled 123mV per count (0x00 - 0xFF)
bc
= VCC scaled 39mV per count (0x00 - 0xFF)
dd
= V5D scaled 39mV per count (0x00 - 0xFF)
eee
= signed Temperature in degrees C (-10 to +60)
ff
= IFLO tune scaled 67mV per count (0x00 - 0xFF)
gg
= SUM tune scaled 54mV per count (0x00 - 0xFF)
hh
= COARSE tune scaled 78mV per count (0x00 - 0xFF)
ii
= FINE tune scaled 89mV per count (0x00 - 0xFF)
l
= 1 if Remote Mode, 0 if Local Mode
Details
<DEV/PACRAS_{cr}
>DEV/PACRAS_abcdefghijk{cr}{lf}] where:
a
= 1 if V15 Fault, else 0 if No Fault
b
= 1 if V14 Fault, else 0 if No Fault
c
= 1 if VCC Fault, else 0 if No Fault
d
= 1 if V5D Fault, else 0 if No Fault
e
= 1 if TEMP Fault, else 0 if No Fault
f
= 1 if IFLO Fault, else 0 if No Fault
g
= 1 if SUM Fault, else 0 if No Fault
h
= 1 if COARSE Fault, else 0 if No Fault
I
= 1 if FINE Fault, else 0 if No Fault
j
= 1 if HSB Fault, else 0 if No Fault
k
= 1 if EXT REF Fault, else 0 if No Fault
8–30
MN/UT4500.IOM
Revision 3