Receive Adjustment - Icom IC-FR6000 Service Manual Addendum

Hide thumbs Also See for IC-FR6000:
Table of Contents

Advertisement

6-3 TRANSMIT ADJUSTMENT (continued)
1) Select an adjustment item using cursor or [↑] / [↓] keys of the PC's keyboard.
2) Set or modify the adjustment value as specifi ed using [←] / [→] keys of the PC's keyboard, then push the [ENTER] key.
ADJUSTMENT
ADJUSTMENT CONDITION
ANALOG
1
DEVIATION
-Preparation-
2 • Connect a Modulation Analyzer
to the TX antenna connector
through an attenuator.
3 • Connect an Audio Generator
to the MIC line through the JIG
cable.
-Adjust-
4 • CH.
• Transmitting
(Wide)
(Middle)
5 • CH.
<[FR6100] only>
• [Wide Band Width]
: "Middle" (see the page 6-4)
• Transmitting
(Narrow)
6 • CH.
• Transmitting
CTCSS/DTCS
1
DEVIATION
-Preparation-
-Adjust-
2 • CH.
• Transmitting

6-4 RECEIVE ADJUSTMENT

1) Select an adjustment item using cursor or [↑] / [↓] keys of the PC's keyboard.
2) Set or modify the adjustment value as specifi ed using [←] / [→] keys of the PC's keyboard, then push the [ENTER] key.
ADJUSTMENT
ADJUSTMENT CONDITION
RECEIVE
1
SENSITIVITY
2 • Connect an SSG to the RX
-Preparation-
antenna connector.
-Adjust-
3 • CH.
(Band center)
• Receiving
For [Low
band] version
-Adjust-
• CH.
(Band center)
• Receiving
For [High
band] version
(Band high)
4 • CH.
• Receiving
• Set the item [TX Mode] to "1."
• Set the Modulation Analyzer as;
HPF
LPF
De-emphasis : OFF
Detector
• Set the Audio Generator as;
Modulation
Level
Wave form
: 1-10
1) Adjust the deviation using [←] / [→]
keys of the PC's keyboard.
2) Push the [ENTER] key to store the
adjust value.
: 1-11
: 1-12
• Set the item [TX Mode] to "3."
: 1-19
1) Adjust the deviation using [←] / [→]
keys of the PC's keyboard.
2) Push the [ENTER] key to store the
adjust value.
• Set the item [RX Mode] to "1."
• Set the SSG as;
Frequency
Level
Modulation
Deviation
: 1-20
1) Set the item [BPF T1 C] to "10."
2) Select the item [BPF T2 C], then
push the [ENTER] key.
: 1-20
• Select the item [BPF C ALL], then
push the [ENTER] key.
: 1-21
• Select the item [BPF H ALL], then
push the [ENTER] key.
6 - 8
OPERATION
: OFF
: 20 kHz
: (P-P)/2
: 1 kHz
: 40 mV rms
: Sine wave
OPERATION
: 400.100 MHz
[FR6000]
450.100 MHz
[FR6100]
: +20 dBμ
: 1 kHz
: 3.5 kHz
ADJUSTMENT
VALUE
ITEM
[TX Mode]
"1"
±4.05–4.15
[MOD (Wide)]
kHz
±3.15–3.25
[MOD (Middle)]
kHz
±2.05–2.15
[MOD (Narrow)]
kHz
[TX Mode]
"3"
±0.68–0.72
[CTCSS]
kHz
ADJUSTMENT
VALUE
ITEM/POINT
[RX Mode]
"1"
[BPF T1 C]
"10"
[BPF T2 C]
(Automatic
[BPF C ALL]
adjustment)
[BPF H ALL]

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ic-fr6100Ic-fr6000-lIc-fr6100h

Table of Contents