Connecting the
Connecting the Polarity Reverser
Polarity Revers-
er and Establish-
NOTE!
ing a Ground
Earth Connec-
If the polarity reverser is incorrectly connected, it can result in poor-quality
weld properties.
tion
▶
1
TSt 2700c MP
Establishing a Ground Earth Connection
Connect grounding cable to the free current socket
1
TSt 2700c MP: Example of ground connection to
the (+) current socket
Connect the polarity reverser according to the wire electrode used.
Check the wire electrode packaging to determine whether the wire electrode
is for (+) or (-) welding.
2
TSt 3500c MP
2
TSt 3500c MP: Example of ground connection to
the
(-) current socket
65