Electrical connection

18
2.
1. If fitted: release the screw of the cover lock for the electronics compartment cover
using the Allen key.
2. Unscrew the cover from the housing and inspect the cover seal.
3. Press the release mechanism and remove the display module.
4. Turn the display module to the desired position: maximum 4 × 90 ° in each direction.
Insert the display module into the desired position until it clicks into place. Screw the
cover tightly back onto the housing. If fitted: tighten the screw of the cover lock using
the Allen key 0.7 Nm (0.52 lbf ft) ±0.2 Nm (±0.15 lbf ft).
In the case of a dual-compartment housing, the display can be mounted in the
electronics compartment as well as in the connection compartment.
5.3

Sliding sleeves

 For more details, see the "Accessories" section.
A
5.4

Post-mounting check

 Is the device undamaged (visual inspection)?
 Does the measuring device meet the measuring point specifications?
For example:
• Process temperature
• Process pressure
• Ambient temperature
• Measuring range
 Are the measuring point number and labeling correct (visual inspection)?
 Is the device adequately protected from wet conditions and direct sunlight?
 Is the device properly secured?
6
Electrical connection
6.1

Required tool

• Screwdriver for electrical connection
• Allen key for screw of cover lock
1.
4 0.7 Nm
4.
Liquiphant FTL51B HART
3.
A0038224