Liquiphant FTL64
Endress+Hauser
 13
Marking and fork position
Screwing in the device
• Turn by the hex bolt only, 15 to 30 Nm (11 to 22 lbf ft)
• Do not turn at the housing!
 14
Screwing in the device
Aligning the cable entry
1.
2.
 15
Housing with external locking screw
The locking screw is not tightened when the device is delivered.
1. Loosen the external locking screw (maximum 1.5 turns).
2. Turn the housing, align the cable entry.
 Avoid moisture in the housing, provide a loop to allow moisture to drain off.
3. Tighten the external locking screw.
5.3

Sliding sleeves

See the Operating Instructions
Installation
3.
4 0.7 Nm
A0034851
A0042423
A0042355
15