Overpressure Limit; State Of Aggregation; Medium Density; Viscosity - Endress+Hauser Liquiphant FTL51B Operating Instructions Manual

Vibronic hart point level switch for liquids
Hide thumbs Also See for Liquiphant FTL51B:
Table of Contents

Advertisement

Liquiphant FTL51B HART
Endress+Hauser
Process pressure range of the sensors
PN
[psi]
[bar]
1450
100
928
64
32
0
-50
-58
1
Permitted pressure rating when the "100 bar (1 450 psi)" option is selected. For exceptions, see the "Process
connections" section. Canadian CRN approval: The maximum permitted process pressure is limited to
90 bar (1 305 psi) only in combination with the CRN approval. More details on the maximum pressure values
are available in the download area of the product page under "www.endress.com".
Optionally available:
• PN: 64 bar (928 psi) at max. 150 °C (302 °F)
• PN: 100 bar (1 450 psi) at max. 150 °C (302 °F)
15.4.4

Overpressure limit

• PN = 64 bar (928 psi): overpressure limit = 1.5·PN maximum100 bar (1 450 psi)
depending on process connection selected
• Membrane burst pressure at 200 bar (2 900 psi)
• PN = 100 bar (1 450 psi): overpressure limit = 1.5·PN maximum150 bar (2 175 psi)
depending on process connection selected
• Membrane burst pressure at 400 bar (5 800 psi)
The device function is limited during the pressure test.
The mechanical integrity is guaranteed at pressures up to 1.5 times the process nominal
pressure (PN).
15.4.5

State of aggregation

Liquid
15.4.6

Medium density

Liquids with density > 0.7 g/cm
Setting > 0.7 g/cm
3
(as-delivered state)
Liquids with density 0.5 to 0.8 g/cm
Setting > 0.5 g/cm
3
(can be ordered as preset value or user-configurable)
Liquids with density > 0.4 g/cm
3
Setting > 0.4 g/cm
(can be ordered as preset value or user-configurable)
15.4.7

Viscosity

≤ 10 000 mPa⋅s
1
0
32
3
3
3
(not for devices with SIL approval)
Technical data
T
+150
[°C]
p
+302
[°F]
A0038268
59

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hart liquiphant ftl51b

Table of Contents