11 SUB FUNCTIONS
11 - 10
Downloaded from
ManualsNet.com
The following is the operation performed during machine OPR control in each OPR
method.
<When OPR method is any of "near-point dog method", "stopper 1",
"stopper 2" and "count 1">
V
OPR. 4
OPR. 5
Pr. 6
<When OPR method is "stopper 3">
V
OPR. 5
Pr. 6
<When OPR method is "count 2">
V
OPR. 4
OPR. 5
Pr. 6
Pr. 6 Bias speed at start, OPR. 4 OPR speed, OPR. 5 Creep speed
OPR. 6 ACC/DEC time at OPR, OPR. 7 DEC/STOP time at OPR
search engine
OPR. 6
OPR. 6
OPR. 6
MELSEC-Q
Near-point dog ON
OPR. 6
Near-point dog ON
OPR. 6
OPR. 6
Machine OPR
control complete
t
Machine OPR
control complete
t
Machine OPR
control complete
t