SECTION 6 - TROUBLESHOOTING
 Codes (300 - 399) Traction Control Module - Fault Condition
Check For These Obvious Conditions First:
• Damage to Traction Control Module wiring harness.
• Confirm that the static ground strap attached under base frame is secure and undamaged.
Table 6-36. Codes (300 - 399) Traction Control Module - Fault Condition
STEP
Recycle machine power 5 times allowing a 10 second interval betwe en
1.
each power recycle. Does fault clear?
Is a code number displaying on the Ground Control Station?
2.
Confirm that both installed batteries are 12 Volt DC.
3.
Check battery voltage while charger is operating. Is voltage within specifi-
4.
cation?
Check for short in harness wires from Ground Control Station connector P5
5.
 to Traction Module (round din plug) .
 Note: This harness contains 6 wires only 3 are used, (See Figure 6-7.) Elec-
trical Diagram.
6-34
ACTION
 – JLG Lift –
SPEC
YES
Done
Code - 316
Go to Step 3
Code - 325
Go to Step 5
12V DC
Go to Step 4
Maximum of
Replace
31 Volts DC
Traction Control
Module
Repair or Replace
Wiring
NO
Go to Step 2
Replace
Traction Control
Module
Replace with proper
Batteries
Repair or Replace
Battery Charger 
3121228