JLG 10MSP Service And Maintenance Manual page 46

Table of Contents

Advertisement

SECTION 6 - TROUBLESHOOTING
6.9 SPECIFICATIONS FOR VARIOUS COMPONENTS
The following table contains specifications for machine components.
COMPONENT
Pump Motor
COMPONENT
Ground Control Module
Traction Control Module
6.10 SPECIAL PIN EXTRACTOR TOOLS FOR ELECTRICAL CONNECTORS
The following table contains pin extractor tools for machine electrical connector components.
Table 6-4. Special Pin Extractor Tools for Electrical Connectors
COMPONENT
Ground Control Station
Drive Motor
Drive Motor Brake
6-16
Table 6-2. Ohm Ratings for Various Components
NOMINAL RESISTANCE @ TEMPERATURE
0.2ohm - 0.4ohm @ 77deg F
Table 6-3. Amperage Draw for Various Components
 95 Amps @ room temperature with rated load
LEVEL SURFACE
(24V) (RATED LOAD)
7 to 11 Amps
(per motor)
DESCRIPTION
For removal of electrical con-
nector pins from the Ground
Control Station connectors.
For removal of electrical con-
nector pins from the Drive
Motor main power connec-
 tors.
For removal of electrical con-
nector pins from the Drive
Motor Brake power connec-
 tors.
 – JLG Lift –
RESISTANCE RANGE POSSIBLE
0.12ohm - 0.49ohm
AMPERAGE
15% GRADE
(24V) (RATED LOAD)
55 to 60 Amps
(per motor)
JLG PART NUMBER
7016618
7002841
7002842
NO LOAD (24V)
3.5 to 4.8 Amps
78 to 86 RPM
ILLUSTRATION
3121228