SECTION 6 - TROUBLESHOOTING
 Code 08 - Right Drive Motor - Disconnected
Check For These Obvious Conditions First:
• Check right drive motor M2 connector at the Traction Control Module for secure and proper connection.
STEP
1.
Check resistance across positive (+) and negative (–) leads in M2 connec-
 tor wiring harness going to the right drive motor. Is reading within spec?
2.
Repair or replace right drive motor wiring, br ushes or motor.
(For brush replacement, see Section 3 of this Service Manual)
Code 09 - Left Brake - Disconnected
Check For These Obvious Conditions First:
• Check left drive motor M1 connector at the Traction Control Module for secure and proper connection.
STEP
Check resistance across positive (+) and negative (–) leads in M1 connec-
1.
 tor wiring harness going to the left drive motor brake assembly. Is reading
within spec?
2.
Repair or replace left brake wirin g or left brake assembly.
Code 10 - Right Brake - Disconnected
Check For These Obvious Conditions First:
• Check right drive motor M2 connector at the Traction Control Module for secure and proper connection.
STEP
1.
Check resistance across positive (+) and negative (–) leads in M2 connec-
 tor wiring harness going to the right drive motor brake assembly. Is reading
within spec?
2.
Repair or replace right brake wiring or right brake assembly.
6-20
Table 6-9. Code 08 - Right Drive Motor Disconnected
ACTION
Table 6-10. Code 09 - Left Brake - Disconnected
ACTION
Table 6-11. Code 10 - Right Brake - Disconnected
ACTION
 – JLG Lift –
SPEC
YES
.1 to .3 ohms
Replace Traction
Module
SPEC
YES
See Table 6-2
Replace Traction
Module
SPEC
YES
See Table 6-2
Replace Traction
Module
NO
Go to Step 2
NO
Go to Step 2
NO
Go to Step 2
3121228