04/15 Rev. 06
Del. prod.profil
Deletion of a product profile from the internal database
Dispense counter
Enables dispense counter (displayed during labelling) to be adjusted by pressing the
Disp. Cnt. Reset
Settings: [Yes, No]
Factory settings
All parameters are factory set to values depending on the relevant machine type. This
factory setting can be reinstalled at any time.
Settings: [No, „Custom defaults", „Factory defaults"]
Custom defaults
Settings: [„Apply current", „Delete"]
Store Parameters
Saves the settings of the functions to a file on the memory card ("FORMATS\" direc-
tory)
Settings: ["With adjust para", „Without adj. par"]
SERVICE MANUAL
and
keys.
• Yes: Dispense counter is set to zero
• No: Dispense counter is not set to zero
All function settings are overwritten by the factory setting.
• No: No factory setting
• „Custom defaults": If customer specific function settings have been stored previ-
Custom
ously (see function
is only visible, if customer settings have already been stored.
• „Factory defaults": The function settings are reset to the factory setting.
• „Apply current": Stores the current function settings as default values. The stored
settings are reinstalled by calling
faults".
• „Delete": Deletes the stored, customer specific settings. „Delete" is only visible, if
settings have already been stored.
• "With adjust para" Parameters that contain devicespecific settings are included in
what is saved. The names of the relevant parameters are marked with a * in the
text file.
Default file name: SETUPALL ALS xxx yy zzzzzzzzzzzzzzzz.FOR
Application: Service
• "Without adj. par": Parameters that contain device-specific settings are excluded
from what is saved.
Default file name: SETUP ALS xxx yy zzzzzzzzzzzzzzzz.FOR
Application: Transferring settings to other devices (when device-specific settings
should not be overwritten).
– xxx = Machine type, e. g. 306
– yy = RH or LH
– zzzzzzzzzzzzzzzz = Serial number of the CPU board
ALX 73x
defaults) those are reinstalled. „Custom defaults"
MACHINE SETUP > Factory settings
Dispenser Parameter menu
MACHINE SETUP menu
= „Custom de-
9