Self-Check; Self-Check Procedure - Renesas Single-Chip Microcomputer M306NKT3 User Manual

Emulation pod for m16c/6n group m16c/6n4, 6n5, 6nk, 6nl, 6nm and 6nn
Table of Contents

Advertisement

M306NKT3-RPD-E User's Manual

2.7 Self-check

2.7.1 Self-check Procedure

To run the self-check of the emulator, do so as explained here below. While the self-check is in progress, the LEDs will change
as shown in Figure 2.6.
(1) If the user system is connected, disconnect it.
(2) Set the switches in the emulation pod to the factory settings as shown in Figure 2.7.
(3) Within 2 seconds of activating power to the emulator, press the system reset switch on the emulator front panel to switch
the emulator to maintenance mode.
(4) Check the SAFE LED starts blinking and then press the system reset switch again.
(5) The self-check will start. If the normal result is displayed in about 30 seconds, the self-check has terminated normally.
P OWE R
P OWE R
SAFE
C LOCK
ERROR
RESE T
RUN
S T A T U S
O F
S YS T EM
HAL T
RESET
(1 ) All the LEDs light
Immediately after turning on the power
Figure 2.6 LED display in the self-check procedure
REJ10J0326-0400 Rev.4.00 Sep. 01, 2006
P OWE R
POWE R
SAF E
C L OCK
ERROR
RE S E T
RU N
S T A TU S OF
SYSTEM
HA L T
RESET
(2 ) SAFE LED blinks
Self - check
: On
: Off
: Blinking
P O WE R
P OWER
SA F E
C L OC K
ER ROR
R E S E T
R UN
S T A T US O F
SYSTEM
H AL T
RESET
Completed normally
POWE R
P O WE R
S A F E
CL OCK
E R R OR
RE S E T
RU N
S T A TU S O F
SYSTEM
HA L T
ERROR LED lights
RESET
System status error
P OWE R
P OWE R
S A F E
C L O C K
E R R OR
R E S E T
R U N
S T A TU S OF
SYSTEM
H A L T
SAFE and ERROR LED blink
RESET
Target status error