3) Example Data Settings
Setting events for wordwise accesses to the even-addresses
STE.W A0,20E8h(A0=5423h)
High-order and low-order data effective
Setting events for wordwise accesses to the odd-addresses
STE.W A0,20E5h(A0=AB79h)
Odd-address high-order data effective
Even-address low-order data effective
Setting events for byte accesses to the even-addresses
STE.B R0L,[A1A0](R0L=E5h,A1=0000h,A0=20E2h)
Low-order data effective
Setting events for byte accesses to the odd-addresses
STE.B R0L,[A1A0](R0L=E6h,A1=0000h,A0=20E3h)
High-order data effective
(4) Setting the combinatorial event condition for the hardware break point
1) Window for setting the combinatorial event condition
REJ10J0326-0400 Rev.4.00 Sep. 01, 2006
3. Usage (How to Use the Emulator Debugger)
Setting a break event
.
A1
Address 1 :0020E8
Data 1
:5423
MASK
:FFFF
Access
:WRITE
Setting a break event
A1
Address 1 :0020E5
Data 1
:AB79
MASK
:FFFF
Access
:WRITE
Setting a break event
A1
Address 1 :0020E2
Data 1
:00E5
MASK
:00FF
Access
:WRITE
Setting a break event
A1
Address 1 :0020E3
Data 1
: 00E6
MASK
: 00FF
Access
:WRITE
Setting the combinatorial event condition
There are following four conditions that you can choose for the
combinatorial events.
- AND
The program breaks when all of the specified events occur.
- AND (Same Time)
The program breaks when the specified events occur at the
same time.
- OR
The program breaks when one of the specified events occurs.
- STATE TRANSITION
The program breaks when the state transition diagram goes
into the break state.
For each event, a pass count (number of passing) is specifiable
(1--255). When "AND" (same time) is specified for Combination,
you can not specify the pass count (fixed to one).
When you have finished setting the combinatorial event
condition, click the "Set" button.