Connecting To An 80-Pin 0.65-Mm-Pitch Foot Pattern (Part 1) - Renesas Emulation Pod M3062NT3-RPD-E User Manual

Emulation pod for m16c/62 group m16c/62n and m16c/30 group m16c/30l
Table of Contents

Advertisement

(2) Connecting to an 80-pin 0.65-mm-pitch Foot Pattern (Part 1)

Here follows how to connect the emulation pod probe to an 80-pin 0.65-mm-pitch foot pattern on the
target system with the M3T-DIRECT80S (not included). For details on the M3T-FLX-DCT613 (not
included) and M3T-DIRECT80S (not included), refer to each user's manual.
(1) Mount the M3T-DIRECT80S to the target system.
(2) Attach the CN2 side of the M30800T-PTC to the tip (CN2 side) of the pitch converter board
connected to the emulation pod probe.
(3) Attach the M30800T-PTC to the M3T-100LCC-DMS.
(4) Attach the M3T-FLX-DCT613 to the M3T-100LCC-DMS.
(5) Attach the M3T-FLX-DCT613 to the M3T-DIRECT80S.
Figure 3.14 Connecting to an 80-pin 0.65-mm-pitch foot pattern (part 1)
Notes on Connecting the Target System:
• Take care not to attach the converter board in a wrong direction. It may cause a fatal
damage to the emulation pod.
• The connectors of the M30800T-PTC are guaranteed for only 50 insertion/removal
iterations.
• The connectors of the M3T-100LCC-DMS, M3T-FLX-DCT613 and M3T-
DIRECT80S are guaranteed for only 20 insertion/removal iterations.
Tip of emulation pod probe
Tip of pitch converter board
CN2 side
(2)
M30800T-PTC
M3T-100LCC-DMS (not included)
(3)
M3T-FLX-DCT613 (not included)
(4)
(5)
M3T-DIRECT80S (not included)
80-pin 0.65-mm-pitch (80P6S-A) foot patern
(1)
No. 1 pin
Target system
CAUTION
( 43 / 84 )

Advertisement

Table of Contents
loading

Table of Contents