5.1.2

M3A-2154 Evaluation Board Power Supply and Setting

The following shows how to set the M3A-2154 Evaluation Board.
Use a 5V DC power supply to feed power to the M3A-2154 Evaluation Board.
Use included 5V power supply cable to connect the 5V DC power supply and CN2 connector
included with the M3A-2154 Evaluation Board.
The Connecting when Feeding Power to the M3A-2154 Evaluation Board is shown in Figure 5.2.
Figure 5.2 Connecting when Feeding Power to the M3A-2154 Evaluation Board
5.1.3

Connecting M3A-2154 Evaluation Board and M32100T-EZ-E

Use an included 10-pin flat cable to connect M32100T-EZ-E and XCN1 connector included with
the M3A-2154 Evaluation Board.
The Connecting M3A-2154 Evaluation Board and M32100T-EZ-E is shown in Figure 5.3.
M32100T-EZ-E
Figure 5.3 Connecting M3A-2154 Evaluation Board and M32100T-EZ-E
5.1.4

Power Supply when Connecting M32100T-EZ-E

-
When turning on power, turn on M32100T-EZ-E first and then the M3A-2154 Evaluation
Board.
-
When turning off power, turn off the M3A-2154 Evaluation Board first and then
M32100T-EZ-E.
When turning on power again after turning off power, wait for 10 seconds.
-
Power to M32100T-EZ-E can be fed from USB cable.
Note: Unless the Starter Kit is powered on this sequence, the kit may operate erratically or break down.
REJ10B0223-0150/Rev.1.50
M3A-2154 evaluation board
CN2
SDI I/F
Mar 2008
32185/32186/32192/32195/32196 Group
Starter Kit User's Manual M3A-2154G52B
4.75-5.25V DC power supply
10-pin flat cable
M3A-2154 evaluation board
XCN1