About Evaluation Board; Contact Failure Of Ic Socket; Cable Connection - Renesas 32185 User Manual

Starter kit
Table of Contents

Advertisement

3.5

About Evaluation Board

When the evaluation board does not start operation after supplied power, check the following
points.
3.5.1

Contact failure of IC Socket

Oscillation or thermal expansion may cause a poor connection between microcomputers and IC
socket on the Evaluation Board. Follow the steps below.
-
Screw down the top cover of IC socket with setscrews at four corners.
The tightening torque shall be 0.054N.m.
Note that only one tight setscrew may cause a poor connection.
The socket included in the evaluation board uses NQPACK and HQPACK by TOKYO ELETECH
CORPORATION.
For more details, visit their website at http://www.tetc.co.jp/e_index.htm.
The following illustrates configuration of M3A-2154G02A (32185/32186/32192/32195/32196
Group Evaluation Board).
Figure 3.2 Configuration of M3A-2154G02A
3.5.2

Cable Connection

-
Make sure the cables are connected to the evaluation board firmly.
REJ10B0223-0150/Rev.1.50
IC socket (HQPACK)
32185/32186/32192/32195/32196 Group evaluation board M3A-2154G02A
Mar 2008
32185/32186/32192/32195/32196 Group
Starter Kit User's Manual M3A-2154G52B
Setscrews on cover
of IC socket
Page 8 of 80

Advertisement