4. Execute the Quick Start Sample Project

This chapter describes the requirements and steps to turn on MCK-RX26T and execute the Quick Start
Sample Project using the switch and the volume on the board. The software to control sensorless vector is
written in RX26T.

4.1 Connect the board and supply power

4.1.1

Jumper pin setting

(1) Inverter Board
Check that the short jumpers are set as following. (Factory default setting)
JP1 : 2-3pin
JP8, JP11 : 1-2pin
JP2, JP3, JP4, JP6, JP12, JP13 : 2-3pin
JP5, JP7, JP9, JP10, JP14, JP15 : 1-2pin
Figure 4-1 Jumper pin setting of Inverter Board
R12QS0060EJ0100 Rev.1.00